This line is applicable to air leakage test of products in fields such as new energy, consumer electronics, household appliances, medical devices, and automotive components.
Process Flow:
The fully automatic air leakage test line requires no manual operation. The equipment automatically completes the following actions: pick up material automatically→air leakage test→sort OK&NG products→receiving
Configuration Description:
Sealing is achieved by pressing with a air cylinder. The jig are customizable according to the product size. The motion mechanism is driven by a air cylinder combined with a linear guide rail, and it is equipped with a safety light curtain.
Product Feature:
1.Long-period operational stability;
2.High-precision intelligent test;
3.Intelligent Internet system;
4.Fully automatic non-standard customization;
5.Professional R&D team.
| Equipment Model | QMJC-DZ-M-01 | ||
| Test Workbench | Single-workbench, Dual-workbench, Quadruple-workbench,Eightfold-workbench( Customizable as Needs) | ||
| Test Method | Direct Pressure Type; Negative Pressure Type;Positive Replacement Type;Differential Pressure Type | ||
| Test Resolution | 0.1Pa | ||
| Test Scale | -80~2000KPa | ||
| Display Unit | Pa、KPa 、bar 、MPa 、psi 、mbar 、mmHg | ||
| Test Time Scale | 9999S | ||
| Pessure Regulation Method | Machanical Pressure Regulation;Electronic Pressure Regulation(Optional) | ||
| Sensor Precision | 0.1%FS | ||
| Historical Data Storage | Supported | ||
| Maiximun Program Group Qty | 100 Groups | ||
| Communication Interface | RS232 + RS485 | ||
| USB Interface | 1个 | ||
| System Language | CN/EN | ||
| MES | Supported | ||
| Environment Temperature | 50 °C ~50°C | ||
| Environment Humidity | ≤80% No Condensation | ||
| Air Source | 0.4~0.8MPa Clean and Dry Compressed Air | ||