High and Low Temperature Test Machine

1.At high temperature, it is applied to test whether there is a softening, weakened performance,feature change, potential damage, or oxidation of the components.
2.At low temperature, it is applied to test whether there is a cracking, embrittlement, movable part jamming or feature change of the components.

Online Consultation

Feature

Process Flow:
Manual loading→set process parameter→activate the equipment→manual  unloading after the test

Product Feature:
1.Precise Control: The temperature control range is adjustable from -70℃ to 150℃ with a precision of ±1℃; the humidity control range is adjustable from 10% to 98%RH with a precision of ±3%RH.
2.Flexible Adjustment: The circulating fan employs variable frequency control, and the air outlet deflectors can be flexibly adjusted in angle to ensure uniform temperature and humidity distribution.
3.Rapid Temperature Change: The average cooling rate under no-load conditions throughout the entire process is over 2.5℃/min.
4.Safe and Reliable: The piping of the humidification and refrigeration systems is separated from the control circuits to prevent circuit damage caused by potential pipe leakage, thereby enhancing safety.

Specifications

Equipment Model HLT-BOX-01 HLT-BOX-02
Loading& Unloading Method  Manual Loading & Unloading
Applicable Product Applicable to the Reliability and Performance Test Under High and Low Temperature, and High-low Temperature Cyclic Alternative Conditions of New Materials Such as Lens Units, Batteries,Printer Components,Car Seats and Steering Wheels.
Temperature Range  -40℃~150℃  -70℃~150℃
Temperature Resolution  0.1℃
Temperature Fluctuation  ≤±0.5℃
Temperature Deviation  ≤±2℃
Temperature Uniformity  ≤±2℃
Heating Rate Average Heating Rate Under No-load Condition ≥3℃/min 
Cooling Rate Average Cooling Rate Under No-load Condition ≥2.5℃/min
Humidity Range  10~98%RH
Humidity Resolution  ±0.1%RH
Humidity Deviation  ≤±3%RH
Humidity  Fluctuation   ≤±3%RH
Refrigeration System Mechanical Compression Single-stage Refrigeration Mechanical Compression  Binary Cascade Refrigeration
Refrigerant  R404a  R404a/R23
Humidity & Temperature Calibration Value  23℃/50%RH and 95℃/50%RH
Cooling Method Air Cooling
Controller  Touch Screen +PLC 
Protective Device  Protect Against Main Power Overcurrent and Current Leakage,Fan Overcurrent,Compressor Super-high/Super-low Pressure,Compressor Overcurrent,Compressor Discharge Overtemperature, Overtemperature inside Chamber, Phase Loss,Air Duct Extreme Overtemperature (257℃) Fusing (Dry Burn),and Overlimit of Temperature Deviation.
Overall Dimension  900*1500*1950mm 900*1600*1950mm
Equipment Weight  420KG 500KG
Power Supply Requirement TN-S  AC380V/50HZ/60HZ   
Air Pressure Requirement  0.4MPa~0.6MPa
Environment Temperature  10℃~30℃
Environment Humidity ≤80% No Condensation